flowcap(8)			SiLK Tool Suite			    flowcap(8)

NAME
       flowcap - Capture, temporarily store, and forward flow data

SYNOPSIS
	 flowcap --destination-directory=DIR
	       --sensor-configuration=FILENAME [--probes=NAME[,NAME...]]
	       --max-file-size=SIZE [--fc-version=NUM]
	       [--timeout=TIMEOUT] [--clock-time[=OFFSET]]
	       [--freespace-minimum=SIZE] [--space-maximum-percent=NUM]
	       [--compression-method=COMP_METHOD]
	       { --log-destination=DESTINATION
		 | --log-pathname=FILE_PATH
		 | --log-directory=DIR_PATH [--log-basename=LOG_BASENAME]
		   [--log-post-rotate=COMMAND] }
	       [--log-level=LEVEL] [--log-sysfacility=NUMBER]
	       [--pidfile=FILE_PATH] [--no-chdir] [--no-daemon]

       Help options:

	 flowcap --sensor-configuration=FILE_PATH
	       { --verify-sensor-config | --verify-sensor-config=VERBOSE }

	 flowcap --help

	 flowcap --version

DESCRIPTION
       flowcap is a daemon that collects data from devices that produce flow
       data (such as a router producing NetFlow v5 or a flow meter producing
       IPFIX (Internet Protocol Flow Information eXport)), temporarily stores
       the data to files on its local disk, and forwards these files to
       rwflowpack(8) for packing.

       As flowcap receives flow records, it stores them in files in the
       location specified by the --destination-directory switch.  These files
       are closed on quantum boundaries, with one file per flow source per
       quantum.	 A quantum is either the amount of time represented by the
       --timeout switch or the file size represented by the --max-file-size
       switch, whichever is reached first.

       To transfer the files to rwflowpack, flowcap works in tandem with the
       rwsender(8) program.  rwsender polls the storage directory and sends
       the files it finds there to an rwreceiver(8) process for processing by
       rwflowpack.

       flowcap produces files that are named PROBE_YYYYMMDDhhmmss.XXXXXX,
       where PROBE is the name of the probe, YYYY is the current year, MM is
       the current month, DD is the current day, hh is the current hour, mm is
       the current minute, ss is the current second, and XXXXXX is a random
       six-character string.

OPTIONS
       Option names may be abbreviated if the abbreviation is unique or is an
       exact match for an option.  A parameter to an option may be specified
       as --arg=param or --arg param, though the first form is required for
       options that take optional parameters.

       For the following options, a SIZE may be given as an ordinary integer,
       or as a real number followed by a suffix "K", "M", "G", or "T", which
       represents the numerical value multiplied by 1,024 (kilo), 1,048,576
       (mega), 1,073,741,824 (giga), and 1,099,511,627,776 (tera),
       respectively.  For example, 1.5K represents 1,536 bytes, or one and
       one-half kilobytes.

   General Configuration Switches
       --destination-directory=DIR
	   Store aggregated packed flow files in this directory for processing
	   by rwsender.	 This switch is required.

       --sensor-configuration=FILENAME
	   Give the path to the configuration file that flowcap will consult
	   to determine how to collect flow records.  The complete syntax of
	   the configuration file is described in the sensor.conf(5) manual
	   page; see also the SiLK Installation Handbook.  This switch is
	   required.

       --probes=NAME[,NAME...]
	   Choose which of the probes described in the sensor configuration
	   file will be used by flowcap.  The default is to use all of the
	   probes defined in the configuration file.  This switch instructs
	   flowcap to only use the specifically named probes.

       --max-file-size=SIZE
	   Set the approximate maximum size of flowcap files to SIZE bytes.
	   If a flowcap file's exceeds SIZE bytes, it will be closed, and a
	   new file will be created and used.  In addition, before opening an
	   output file, flowcap ensures there are SIZE bytes of free space
	   available, and exits if there is not.  This switch is required.

       --timeout=TIMEOUT
	   Set the maximum duration that a flowcap output file remains open to
	   TIMEOUT seconds.  When the --clock-time switch is given, the first
	   duration will be less than TIMEOUT seconds.	If the --timeout
	   switch is not specified, flowcap uses a default of 60 seconds.

       --clock-time[=OFFSET]
	   Force flowcap to close its files at predictable times.  When this
	   switch is provided, flowcap closes its output files at OFFSET
	   seconds after midnight (UTC of the current day) and at every
	   TIMEOUT seconds thereafter.	The default value of OFFSET is 0.  For
	   example, --timeout=900 --clock-time=300 causes flowcap to close its
	   output files at the 05, 20, 35, and 50 minute points in each hour.
	   Even with this switch, files will still be closed if they exceed
	   the size specified by --max-file-size.

       --fc-version=NUM
	   Choose the record version for the files of IPv4 flow records that
	   flowcap produces.  Valid values are 2, 3, 4, and 5, and the default
	   is 5.  This switch is ignored for probes that support IPv6
	   addresses.

       --freespace-minimum=SIZE
	   Set the minimum free space to maintain on the file system where the
	   --destination-directory is located.	By default, flowcap assumes
	   that it has full rein over the file system on which it writes its
	   files.  The default is to leave 1GB of free space.  If flowcap
	   fills this space, it will exit.  Flows arriving during this time
	   will be lost.  See also --space-maximum-percent.

       --space-maximum-percent=NUM
	   Use no more than this percentage of the file system containing the
	   --destination-directory.  The default is to use no more than 98% of
	   the file system.  If flowcap fills this space, it will exit.	 See
	   also --freespace-minimum.

       --compression-method=COMP_METHOD
	   Specify how to compress the output.	When this switch is not given,
	   flowcap files are compressed using the "best" method, regardless of
	   the default chosen when SiLK was compiled.  The valid values for
	   COMP_METHOD are determined by which external libraries were found
	   when SiLK was compiled.  To see the available compression methods
	   and the default method, use the --help or --version switch. SiLK
	   can support the following COMP_METHOD values when the required
	   libraries are available.

	   none
	       Do not compress the output using an external library.

	   zlib
	       Use the zlib(3) library for compressing the output.  Using zlib
	       produces the smallest output files at the cost of speed.

	   lzo1x
	       Use the lzo1x algorithm from the LZO real time compression
	       library for compression.	 This compression provides good
	       compression with less memory and CPU overhead.

	   best
	       Use lzo1x if available, otherwise use zlib.

       --verify-sensor-config
       --verify-sensor-config=VERBOSE
	   Verify that the syntax of the sensor configuration file is correct
	   and then exit flowcap.  If the file is incorrect or if it does not
	   define any probes, an error message is printed and flowcap exits
	   abnormally.	If the file is correct and no argument is provided to
	   the --verify-sensor-config switch, flowcap simply exits with status
	   0.  If an argument (other than the empty string and 0) is provided
	   to the switch, the names of the probes found in the sensor
	   configuration file are printed to the standard output, and then
	   flowcap exits.

       --help
	   Print the available options and exit.

       --version
	   Print the version number and information about how SiLK was
	   configured, then exit the application.

   Logging and Daemon Configuration Switches
       The switches in this section determine the type of log messages that
       flowcap generates and where those messages are written.

       One of the following switches are required:

       --log-destination=DESTINATION
	   Specify the destination where logging messages are written.	When
	   DESTINATION begins with a slash "/", it is treated as a file system
	   path and all log messages are written to that file; there is no log
	   rotation.  When DESTINATION does not begin with "/", it must be one
	   of the following strings:

	   "none"
	       Messages are not written anywhere.

	   "stdout"
	       Messages are written to the standard output.

	   "stderr"
	       Messages are written to the standard error.

	   "syslog"
	       Messages are written using the syslog(3) facility.

	   "both"
	       Messages are written to the syslog facility and to the standard
	       error (this option is not available on all platforms).

       --log-directory=DIR_PATH
	   Use DIR_PATH as the directory to which the log files are written;
	   DIR_PATH must be a complete directory path.	The log files have the
	   form

	    DIR_PATH/LOG_BASENAME-YYYYMMDD.log

	   where YYYYMMDD is the current date and LOG_BASENAME is the
	   application name or the value passed to the --log-basename switch
	   when provided.  The log files are rotated: At midnight local time,
	   a new log is opened, the previous file is closed, and the command
	   specified by --log-post-rotate is invoked on the previous day's log
	   file.  (Old log files are not removed by flowcap; the administrator
	   should use another tool to remove them.)  When this switch is
	   provided, a process-ID file (PID) is also written in this directory
	   unless the --pidfile switch is provided.

       --log-pathname=FILE_PATH
	   Use FILE_PATH as the complete path to the log file.	The log file
	   is not rotated.

       The following switches are optional:

       --log-level=LEVEL
	   Set the severity of messages that will be logged.  The levels from
	   most severe to least are: "emerg", "alert", "crit", "err",
	   "warning", "notice", "info", "debug".  The default is "info".

       --log-sysfacility=NUMBER
	   Set the facility that syslog(3) uses for logging messages.  This
	   switch takes a number as an argument.  The default is a value that
	   corresponds to "LOG_USER" on the system where flowcap is running.
	   This switch produces an error unless --log-destination=syslog is
	   specified.

       --log-basename=LOG_BASENAME
	   Use LOG_BASENAME in place of the application name in the name of
	   log files in the log directory.  See the description of the
	   --log-directory switch.  This switch does not affect the name of
	   the process-ID file.

       --log-post-rotate=COMMAND
	   Run COMMAND on the previous day's log file after log rotation.
	   When this switch is not specified, the previous day's log file is
	   compressed with gzip(1).  When the switch is specified and COMMAND
	   is the empty string, no action is taken on the log file.  Each
	   occurrence of the string %s in COMMAND will be replaced with the
	   full path to the log file, and each occurrence of "%%" will be
	   replaced with "%".  If any other character follows "%", flowcap
	   exits with an error.	 Specifying this switch without also using
	   --log-directory is an error.

       --pidfile=FILE_PATH
	   Set the complete path to the file in which flowcap writes its
	   process ID (PID) when it is running as a daemon.  No PID file is
	   written when --no-daemon is given.  When this switch is not
	   present, no PID file is written unless the --log-directory switch
	   is specified, in which case the PID is written to
	   LOGPATH/flowcap.pid.

       --no-chdir
	   Do not change directory to the root directory.  When flowcap
	   becomes a daemon process, it changes its current directory to the
	   root directory so as to avoid potentially running on a mounted file
	   system.  Specifying --no-chdir prevents this behavior, which may be
	   useful during debugging.  The application does not change its
	   directory when --no-daemon is given.

       --no-daemon
	   Force flowcap to run in the foreground---it does not become a
	   daemon process.  This may be useful during debugging.

ENVIRONMENT
       SILK_IPFIX_PRINT_TEMPLATES
	   When set to 1, flowcap writes messages to the log file describing
	   each IPFIX and NetFlow v9 template it receives.  The first message
	   includes the domain, the template identifier, the number of
	   information elements in the template, and the name of this
	   environment variable.  Next, a message is printed for each
	   information element in the template where the message contains the
	   domain id, the template id, and the element's position in the
	   template, length in octets, numeric information element identifier,
	   and name.  For elements defined by a private enterprise, the IE
	   number has two parts: the private enterprise number and the
	   information element number, separated by a slash (/).  (Requires
	   libfixbuf 1.4.0 or later.)  Since SiLK 3.8.2.

       SILK_LIBFIXBUF_SUPPRESS_WARNINGS
	   When set to 1, flowcap disables all warning messages generated by
	   libfixbuf.  These warning messages include out-of-sequence packets,
	   data records not having a corresponding template, record count
	   discrepancies, and issues decoding list elements.  Since SiLK
	   3.10.0.

FILES
       sensor.conf
	   The location of this file must be specified by the
	   --sensor-configuration switch.  This file specifies probe blocks
	   that tell flowcap how to capture data.  The syntax of this file is
	   described in the sensor.conf(5) manual page.

SEE ALSO
       sensor.conf(5), rwflowpack(8), rwsender(8), rwreceiver(8), silk(7),
       syslog(3), zlib(3), gzip(1), SiLK Installation Handbook

SiLK 3.11.0.1			  2016-02-19			    flowcap(8)
[top]

List of man pages available for DragonFly

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net