DS2760 man page on DragonFly

Man page or keyword search:  
man Server   44335 pages
apropos Keyword Search (all sections)
Output format
DragonFly logo
[printable version]

DS2760(3)		     One-Wire File System		     DS2760(3)

NAME
       DS2760, DS2761, DS2762 - High-Precision Li+ Battery Monitor

SYNOPSIS
   Temperature Voltage and Current.
       30   [.]XXXXXXXXXXXX[XX][/[   amphours	|   current  |	currentbias  |
       lock.[0-1|ALL] | memory | pages/page.[0-1|ALL] | PIO | sensed | temper‐
       ature | vbias | vis | volt | volthours |
       cc | ce | coc | defaultpmod | defaultswen | dc | de | doc | mstr | ov |
       ps | pmod | swen | uv |
       ]]

   Thermocouple
       30   [.]XXXXXXXXXXXX[XX][/[    temperature    |	  typeX/range_low    |
       typeX/range_high | typeX/temperature ]]

   Weather Station
       30   [.]XXXXXXXXXXXX[XX][/[   WS603/temperature	|  WS603/wind_speed  |
       WS603/direction | WS603/volt |
       WS603/LED/status | WS603/LED/control.ALL | WS603/LED/model |
       WS603/calibrationwind_speed | WS603/calibration/direction |
       WS603/light/intensity | WS603/light/threshold

FAMILY CODE
       30

SPECIAL PROPERTIES
   amphours
       read-write, floating point
       Accumulated amperage read  by  current  sensor.	Units  are  in	Amp-hr
       (Assumes internal 25mOhm resistor). Derived from volthours / Rinternal.
       Formally amphours is the integral of current - currentbias over time.

   current
       read-only, floating point
       Current	reading. Units are in Amp (Assumes internal 25 mOhm resistor).
       Derived from vis / Rinternal.

   currentbias
       read-write, floating point
       Fixed offset applied to each current measurement. Used in the  amphours
       value.  Assumes	internal 25mOhm resistor. Units are Amp and range from
       -.08A to .08A.
       Derived from vbias / Rinternal.

   lock.[0-1|ALL]
       read-write, yes-no
       Lock either of the two eprom pages to prevent  further  writes.	Appar‐
       ently setting lock is permanent.

   memory
       read-write, binary
       Access  to  the	full  256  byte	 memory	 range.	 Much of this space is
       reserved or special use. User space is the page area.
       See the DATASHEET for a full memory map.

   pages/pages.[0-1|ALL]
       read-write, binary Two 16 byte areas of memory  for  user  application.
       The lock property can prevent further alteration.
       NOTE that the page property is different from the common OWFS implemen‐
       tation in that all of memory is not accessible.

   PIO
       write-only, yes-no
       Controls the PIO pin allowing external switching.
       Writing "1" turns the PIO pin on (conducting). Writing  "0"  makes  the
       pin  non-conducting.  The logical state of the voltage can be read with
       the sensed property. This will reflect the current voltage at the  pin,
       not the value sent to PIO
       Note  also  that	 PIO  will  also be altered by the power-status of the
       DS2670 See the datasheet for details.

   sensed
       read-only, yes-no
       The logical voltage at the PIO pin. Useful only if the PIO property  is
       set to "0" (non-conducting).
       Value will be 0 or 1 depending on the voltage threshold.

   temperature
       read-only, floating point
       Temperature  read  by the chip at high resolution (~13 bits). Units are
       selected from the invoking command line. See owfs(1) or owhttpd(1)  for
       choices. Default is Celsius.
       Conversion is continuous.

   vbias
       read-write, floating point
       Fixed  offset  applied  to each vis measurement. Used for the volthours
       value. Units are in Volts.
       Range -2.0mV to 2.0mV

   vis
       read-only, floating point
       Current sensor reading (unknown external resistor). Measures the	 volt‐
       age gradient between the Vis pins. Units are in Volts
       The  vis	 readings  are	integrated  over time to provide the volthours
       property.
       The current reading is derived from vis assuming the internal  25  mOhm
       resistor is employed. There is no way to know this through software.

   volt
       read-only, floating point
       Voltage	read  at  the  voltage	sensor;. This is separate from the vis
       voltage that is used for current measurement. Units are Volts
       Range is between 0 and 4.75V

   volthours
       read-write, floating point
       Integral of vis - vbias over time. Units are in volthours

THERMOCOUPLE
   typeX/
       directory
       Thermocouple circuit using the DS2760 to read the Seebeck  voltage  and
       the  reference temperature. Since the type interpretation of the values
       read depends on the type of thermocouple, the correct directory must be
       chosen.	Supported thermocouple types include types B, E, J, K, N, R, S
       and T.

   typeX/range_low typeX/ranges_high
       read-only, flaoting point
       The lower and upper temperature	supported  by  this  thermocouple  (at
       least  by  the conversion routines). In the globally chosen temperature
       units.

   typeX/temperature
       read-only, floating point
       Thermocouple temperature. Requires a voltage  and  temperature  conver‐
       sion. Returned in globally chosen temperature units.
       Note:  there  are  two  types of temperature measurements possible. The
       temperature value in the main device directory is the reference temper‐
       ature  read  at the chip. The typeX/temperature value is at the thermo‐
       couple junction, probably remote from the chip.

WEATHER STATION
   WS603
       directory
       Weather station from AAG electronica that  includes  temperature,  wind
       speed, wind direction, light sensor and LED lights.

   WS603/temperature
       read-only, floating-point
       Uses  the DS2760 temperature sensor. This is equivalent to the tempera‐
       ture value. Again in the specificed temperature scale, default Celsius.

   WS603/wind_speed
       read_only, floating-point
       Readings	 from  the   anometer,	 scaled	  using	  the	WS603/calibra‐
       tion/wind_speed

   WS603/direction
       read_only, unsigned integer
       Wind direction, using the following table

       1      N

       2      NNE

       3      NE

       4      NEE

       5      E

       6      EES

       7      ES

       8      ESS

       9      S

       10     SSW

       11     SW

       12     SWW

       13     W

       14     WWN

       15     WN

       16     WWN

       Values  are  adjusted  (internally)  by the WS603/calibration/direction
       property

   WS603/volt
       read-only, unsigned integer
       Voltage value from the WS603 device. Units and significance is unclear.

   WS603/calibration/wind_speed
       read-write, unsigned integer
       Value between 1 and 200 for wind speed scaling. Values on of this range
       are ignored and the default value of 100 used.

   WS603/calibration/direction
       read-write, unsigned integer
       Adjustment of wind direction. See datasheet.

   WS603/light/intensity
       read-only, unsigned integer
       Uncalibrated  value  from an internal light sensor. Used for control of
       LED display (daytime vs nighttime).

   WS603/light/threshold
       read-only, unsigned integer
       Threshold for internal light sensor. Used for control  of  LED  display
       (daytime vs nighttime).

       Value is set as value 4 of the array passed to WS603/LED/control

   WS603/LED/status
       read-only, unsigned integer
       Status of LED lights intensities. See datasheet.

       Value is set as values 2 and 3 of the array passed to WS603/LED/control

   WS603/LED/model
       read-only, unsigned integer
       What factors control LED display. See datasheet.

       Value is set as value 1 of the array passed to WS603/LED/control.ALL

   WS603/LED/model
       write-only, unsigned integer array of 4 values
       Four  integers  sent  to	 control  LED display. All four values must be
       sent, comma separated.

       0      Light mode

       1      Light status

       2      Light level

       3      Light threshold

OBSCURE PROPERTIES
   cc ce coc dc de doc mstr ov pmod swen uv
       varies, yes-no
       Bit flags corresponding to various battery management functions of  the
       chip. See the DATASHEET for details of the identically named entries.
       In general, writing "0" corresponds to a 0 bit value, and non-zero cor‐
       responds to a 1 bit value.

   defaultpmod defaultswen
       read-write, yes-no
       Default power-on state for the corresponding properties.

STANDARD PROPERTIES
ALARMS
       None.

DESCRIPTION
   DS2760 DS2761 DS2762
       The DS2760 (3) is a class of battery charging  controllers.  There  are
       minor hardware difference between the DS2760, DS2761 and DS2762 battery
       chip, but they are indistiguishable to the software.

       A number of interesting devices can be built with the DS276x  including
       thermocouples.  Support	for  thermocouples in built into the software,
       using the embedded thermister as the cold junction temperature.

       For an explanation of the differences between the DS276x variants,  see
       Dallas Application Note 221.

ADDRESSING
DATASHEET
       http://pdfserv.maxim-ic.com/en/ds/DS2760.pdf
       http://pdfserv.maxim-ic.com/en/an/app221.pdf
       http://www.aag.com.mx/aagusa/contents/en-us/Descrip‐
       tion%20of%20WSV3%20Interface%20(1-wire).pdf

SEE ALSO
AVAILABILITY
       http://www.owfs.org

AUTHOR
       Paul Alfille (paul.alfille@gmail.com)

OWFS Manpage			     2003			     DS2760(3)
[top]

List of man pages available for DragonFly

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net