SG_MODES(8)			   SG3_UTILS			   SG_MODES(8)

NAME
       sg_modes - reads mode pages with SCSI MODE SENSE command

SYNOPSIS
       sg_modes [--all] [--control=PC] [--dbd] [--dbout] [--examine] [--flexi‐
       ble] [--help] [--hex] [--list] [--llbaa] [--page=PG[,SPG]] [--raw] [-R]
       [--six] [--verbose] [--version] [DEVICE]

       sg_modes [-6] [-a] [-A] [-c=PC] [-d] [-D] [-e] [-f] [-h] [-H] [-l] [-L]
       [-p=PG[,SPG]] [-r] [-subp=SPG] [-v] [-V] [-?] [DEVICE]

DESCRIPTION
       This utility sends a MODE SENSE SCSI command to the DEVICE and  outputs
       the  response.  There is a 6 byte and 10 byte (cdb) variant of the MODE
       SENSE command, this utility defaults to the 10 byte variant.

       This utility decodes mode page headers and block descriptors  but  out‐
       puts  the contents of each mode page in hex. It also has no facility to
       change the mode page contents or block descriptor data. Mode page  con‐
       tents are decoded and can be changed by the sdparm utility.

       This  utility  supports two command line syntaxes, the preferred one is
       shown first in the synopsis and explained in this section. A later sec‐
       tion  on	 the  old  command  line  syntax  outlines the second group of
       options.

       If no page is given (and --list is not selected) then --all is assumed.
       The --all option requests all mode pages (but not subpages) in a single
       response.

OPTIONS
       Arguments to long options are mandatory for short options as well.

       -a, --all
	      output all the mode pages reported by the DEVICE. This  is  what
	      the  page	 code 63 (0x3f) is defined to do. When used once, mode
	      subpages are not fetched. When used twice (e.g. '-aa'), all mode
	      pages   and  subpages  are  requested  which  is	equivalent  to
	      '--page=63,255'.

       -c, --control=PC
	      PC is the page control value. Up to four different  versions  of
	      each page are held by the device:
		0 : current values (i.e. those active at present)
		1 : changeable values
		2 : default values (i.e. the manufacturer's settings)
		3 : saved values
	      The  changeable  values are bit masks showing which fields could
	      be changed  with	a  MODE	 SELECT.  The  saved  values  will  be
	      re-instated  the	next time the device is power cycled or reset.
	      If this option is not given then current values [0] are assumed.

       -d, --dbd
	      disable block descriptors. By default, block  descriptors	 (usu‐
	      ally  one	 (for  disks)  or  none)  are returned in a MODE SENSE
	      response. This option sets the "disable block descriptors" (DBD)
	      bit  in  the  cdb	 which	instructs the device not to return any
	      block descriptors in its response. Older devices may not support
	      this  setting  and  may  return  an "illegal request" sense key;
	      alternatively they may ignore it. Oddly the Reduced  Block  Com‐
	      mand set (RBC) requires this bit set.

       -D, --dbout
	      disable  outputting  block  descriptors. Irrespective of whether
	      block descriptors are present in the response or not,  they  are
	      not output.

       -e, --examine
	      examine each mode page in the range 0 through to 62 (inclusive).
	      If some response is given then print out the mode page  name  or
	      number (in hex) if the name is not known.

       -f, --flexible
	      Some  devices, bridges and/or drivers attempt crude translations
	      between MODE SENSE 6 and 10 byte commands without correcting the
	      response.	 This  will  cause  the response to be mis-interpreted
	      (usually with an error saying the response is  malformed).  With
	      this  option,  the  length of the response is checked, and if it
	      looks wrong, the response is then decoded as if the  other  mode
	      sense (cdb length) was sent.

       -h, --help
	      print out the usage message then exit.

       -H, --hex
	      The  default  action  is	to decode known mode page numbers (and
	      subpage numbers) into text. When this option is used  once,  the
	      response	is  output  in	hexadecimal.  When this option is used
	      twice, mode page numbers and page control values are  output  in
	      hex.

       -l, --list
	      lists all common page and subpage codes and their names that are
	      found in the command set that matches the peripheral type of the
	      given  DEVICE.   If no DEVICE and no --page=PG is given then the
	      common page and subpage codes and their names are listed for SBC
	      (e.g.  a	disk).	If no DEVICE is given and a --page=PG is given
	      then the common page and	subpage	 codes	and  their  names  are
	      listed  for the command set whose peripheral device type matches
	      the value given to PG. For  example  'sg_mode  --list  --page=1'
	      lists  the  command  mode	 pages	and subpages for tape devices.
	      Additionally if a sub_page_code is given then it is  interpreted
	      as  a  transport	identifier and command transport specific mode
	      page codes and their names are listed following  the  main  mode
	      page list.  Other options are ignored.

       -L, --llbaa
	      set  the	Long  LBA  Accepted (LLBAA) bit in the MODE SENSE (10)
	      cdb. This bit is not defined in the MODE SENSE (6) cdb  so  set‐
	      ting  the '-L' and '--six' options is reported as an error. When
	      set the DEVICE may respond with 16  byte	block  descriptors  as
	      indicated	 by the 'LongLBA' field in the response. In most cases
	      setting this option is not needed.

       -O, --old
	      switch to older style options.

       -p, --page=PG
	      page code to fetch. The PG is assumed  to	 be  a	decimal	 value
	      unless  prefixed	by  '0x' or has a trailing 'h'. It should be a
	      value between 0 and 63 (inclusive). When not given and a default
	      is  required  then  a value of 63 (0x3f), which fetches all mode
	      pages, is used.

       -p, --page=PG,SPG
	      page code and subpage code values to fetch. Both	arguments  are
	      assumed  to  be  decimal unless flagged as hexadecimal. The page
	      code should be between 0 and  63	inclusive.  The	 subpage  code
	      should be between 0 and 255 inclusive. The default value for the
	      subpage code is 0.

       -r, --raw
	      output the response in binary  to	 stdout.  Error	 messages  and
	      warnings,	 if  any, are sent to stderr. When this option is used
	      twice (e.g. '-rr') then has the same action as '-R'

       -R     output the selected mode page to stdout a byte  per  line.  Each
	      line  contains  two  hexadecimal	digits	(e.g. "3e"). Useful as
	      input (after editing) to the sg_wr_mode(8) utility.

       -6, --six
	      by default this utility sends a 10 byte MODE  SENSE  command  to
	      the  DEVICE.  However some SCSI devices only support 6 byte MODE
	      SENSE commands (e.g. SCSI-2 tape drives). This parameter	forces
	      the use of 6 byte MODE SENSE commands.

       -v, --verbose
	      increase level of verbosity. Can be used multiple times.

       -V, --version
	      print out version string then exit.

NOTES
       If  the	normal	sg_modes utility fails with "illegal command operation
       code" then try the '--six' (or '-6') option.

       This utility performs a SCSI INQUIRY command to determine  the  periph‐
       eral  type  of the device (e.g. 0 -> Direct Access Device (disk)) prior
       to sending a MODE SENSE command.	 This  helps  in  decoding  the	 block
       descriptor and mode pages.

       In  the	2.4  series of Linux kernels the DEVICE must be a SCSI generic
       (sg) device. In the 2.6 series block devices (e.g. SCSI disks  and  DVD
       drives)	can also be specified. For example "sg_modes -a /dev/sda" will
       work in the 2.6 series kernels.

EXIT STATUS
       The exit status of sg_modes is 0 when it is successful.	Otherwise  see
       the sg3_utils(8) man page.

OLDER COMMAND LINE OPTIONS
       The  options  in	 this  section	were  the only ones available prior to
       sg3_utils version 1.23 . In sg3_utils  version  1.23  and  later	 these
       older  options can be selected by either setting the SG3_UTILS_OLD_OPTS
       environment variable or using '--old' (or '-O) as the first option.

       -6     by default this utility sends a 10 byte MODE  SENSE  command  to
	      the  DEVICE.  This parameter forces the use of 6 byte MODE SENSE
	      commands.	 See --six in the main description.

       -a     see --all in the main description.

       -A     output all the mode pages and subpages supported by the  DEVICE.
	      Same as '--all --all' in the new syntax.

       -c=PC  PC  is  the  page	 control  value.  See --control=PC in the main
	      description.

       -d     see --dbd in the main description.

       -D     see --dbout in the main description.

       -e     see --examine in the main description.

       -f     see --flexible in the main description.

       -h     The default action is to decode known  mode  page	 numbers  (and
	      subpage  numbers)	 into text. With this option mode page numbers
	      (and subpage numbers) are output in hexadecimal.

       -H     same action as the '-h' option.

       -l     see --list in the main description.

       -L     see --llbaa in the main description.

       -N     switch to the newer style options.

       -p=PG  PG is page code to fetch. Should be a hexadecimal number between
	      0	 and  3f  inclusive  (0 to 63 decimal). The default value when
	      required is 3f (fetch all mode pages).

       -p=PG,SPG
	      page code and subpage code values to fetch. The page code should
	      be  a hexadecimal number between 0 and 3f inclusive. The subpage
	      code should be a hexadecimal number between 0 and ff  inclusive.
	      The default value for the subpage code is 0.

       -r     output  the  selected  mode page to stdout a byte per line. Each
	      line contains two hexadecimal  digits  (e.g.  "3e").  Useful  as
	      input (after editing) to the sg_wr_mode(8) utility.

       -subp=SPG
	      sub page code to fetch. Should be a hexadecimal number between 0
	      and 0xff inclusive. The default value is 0.

       -v     increase verbosity of output.

       -V     print out version string then exit.

       -?     output usage message then exit. Ignore all other parameters.

AUTHOR
       Written by Doug Gilbert

REPORTING BUGS
       Report bugs to <dgilbert at interlog dot com>.

COPYRIGHT
       Copyright © 2000-2007 Douglas Gilbert
       This software is distributed under the GPL version 2. There is NO  war‐
       ranty;  not  even  for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR‐
       POSE.

SEE ALSO
       sdparm(8),  sg_wr_mode(8),   sginfo(8),	 sgmode(scsirastools),	 scsi‐
       info(net), scu(net), seatools(seagate)

       All  these  utilities offer some facility to change mode page (or block
       descriptor) parameters.

sg3_utils-1.24			 February 2007			   SG_MODES(8)
[top]

List of man pages available for YellowDog

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net